Switching Losses in a GTO Inverter for Induction Heating

authored by
Axel Mertens, Hans Christoph Skudelny
Abstract

In a parallel resonant inverter using gate-turn-off thyristors (GTO’s), the turn-off losses can be reduced by gate-assisted turnoff technique, while turn-on losses contribute significantly to the total switching losses. For optimum operation of the GTO, the total switching losses have to be minimum. On the basis of loss measurement, an optimum mode of operation is suggested.

External Organisation(s)
RWTH Aachen University
Type
Article
Journal
IEEE Transactions on Power Electronics
Volume
6
Pages
93-99
No. of pages
7
ISSN
0885-8993
Publication date
01.1991
Publication status
Published
Peer reviewed
Yes
ASJC Scopus subject areas
Electrical and Electronic Engineering
Electronic version(s)
https://doi.org/10.1109/63.65007 (Access: Closed)