Using magneto-optical measurements for the evaluation of a hybrid magnetic shape memory (MSM)-based microactuator

verfasst von
B. Spasova, M. C. Wurz, C. Ruffert, J. Norpoth, Ch Jooss, H. H. Gatzen
Abstract

Magnetic shape memory (MSM) materials present a new class of alloys, which can be used for creating electromagnetic microactuators facilitating a linear motion. The concept of the hybrid MSM microactuator pursued is using a pair of discrete MSM strips sandwiched between microstators. For the microstator fabrication, MEMS technology is applied. The two MSM strips are elongated alternatively, with one strip showing strain when exposed to a magnetizing field, while the other one is mechanically collapsed by its elongating counterpart, and vice versa. For inducing the elongation in the MSM strips, a critical field strength Hcrit has to be exceeded in vertical direction within the MSM strip. For analyzing what magnetic field strength is reached by the microstators and if it is greater than the critical field strength Hcrit required to inducing a reorientation of the twin variants in the MSM material, magneto-optical measurements were carried out.

Organisationseinheit(en)
Institut für Mikroproduktionstechnik
Externe Organisation(en)
Georg-August-Universität Göttingen
Typ
Artikel
Journal
IEEE transactions on magnetics
Band
46
Seiten
2256-2259
Anzahl der Seiten
4
ISSN
0018-9464
Publikationsdatum
06.2010
Publikationsstatus
Veröffentlicht
Peer-reviewed
Ja
ASJC Scopus Sachgebiete
Elektronische, optische und magnetische Materialien, Elektrotechnik und Elektronik
Elektronische Version(en)
https://doi.org/10.1109/TMAG.2010.2040719 (Zugang: Unbekannt)